Sign In >>


SUPPORT

The New TRACE MODE SCADA/HMI Release 6.10.2 Available For Download

TRACE MODE SCADA/HMIAdAstrA Адастра SCADAAdAstra Research Group, Ltd (Moscow, Russia) has announced a new release of integrated SCADA- and SOFTLOGIC- system TRACE MODE 6.10.2. The release is now available for all registered users of TRACE MODE 6 SCADA/HMI for free (it is free for download  from the  User's Personal Account).

TRACE MODE 6.10.2 – New In Release

Unauthorized Access Security Upgraded
 
In accordance to increased security requirements of unauthorized access and user authentification in the process control software, new means of user rights management have been introduced.

TRACE MODE SCADA/HMI logoNew Features Added

1. The constraint of the inter-node bindings number used while sending of Alarm report (AR) messages with use of the key ALANET_SEND_TONODE has been removed. If there are GEs (graphic elements) on node panels (consoles), which do display messages from the Alarm report, then the node will receive network broad-casts of messages coming from AR-server automatically. It’s assumed that a node CONSOLE has bindings for data display.
2. The specification of AR-message categories has been extended. Additional categories, which do not require acknowledgments, have been introduced. If the filter «Non-acknowledged» applied, then such messages are not displayed.
3. The cut-through message broad-casting about acknowledgements of AR-messages between nodes is introduced. The broadcastings are:

  • from server to all the nodes are of the CONSOLE type, that are receiving these messages;
  • from a CONSOLE-node to the server.

4. Programmable and interactive e-mail sending feature for any node user has been enabled.
5. GEs «Contour» and «Rectangle» are transferred to a group «Flat Figures».

Detected Bugs Fixed

1. Tools of the file-document importation, headers/footers forming, trends with legend generation, formatting the output of variables during editing and document generation are resumed.
2. Control functions in GE «Contour» are restored.
3. The bug in displaying of discrete signals on trend has been fixed.
4. The display of discrete (on/off) indicators has been stabilized.
5. On the panel, for eGE «Date and Time», which has no link to an argument, the current time-value indication on panel and its components are supported.
6. HMI editor’s stability is more up while compiling screen templates with graphic objects, which lost own linking to components of «Resources» layer (because of wrong project development practices (such as incorrect editing of screens and resource libraries, also import of screen templates).
7. Critical situation in procedure of «Re-linking of CALL channel arguments» fixed.
8. A function of the value input into a channel has been resumed. This is applicable in the profiler rmg32.exe and also in MicroRTM, in the channel tree, without expanding an attribute tree.
9. In MicroRTM a specification of «COM-port destination» has been enlarged, for interconnecting to devices by means of the channel CALL.Vector (E_Meter, Master and Mlink are added).
10. Recalculation setting "by time" of the channel process period have been re-organized.
11. A universal function of GSM-modems initialization has been resumed.
12. In the KR-500 (TCP) driver control commands specification has been extended, being adapted for setup of the free-hand number of controller.

Attention! While using release of 6.10.2, it is to take into account the following:

1. Because TRACE MODE DataCenter was not updated since 6.09.2. Use Data Center 6.09.2 if required.

a. For the EmbeddedConsole node it’s to use a folder, created and compiled in the IDE 6.10.
    The IDE 6.10 can be downloaded from the Trace Mode User Account on www.tracemode.com if required.
b.
In the RTM starting configuration file for the node to which the EmbeddedConsole node is linked, enter a key OXP_START=ON.

2. Projects of releases 6.10 and earlier may be converted into format of 6.10.2 after sequential opening of screen templates and graphic panels, one by another, in IDE 6.10.2.
3. Output formats in Grpahic Panels (GP) are changed. In view of that, in some cases (when eGE are inherited out of old releases), changes in graphic forms executed in real-time are possible. When needed, appropriate eGE are to be open and edited. In particular, one can change display formats of text-related eGE, from Default to Auto.
.
4. In view of optimization applied to the visualization means of GP, dimensions of GP within one single node must be identical.

5. User component libraries (tmdevenv.tmul) of base and professional lines (IDEs) are placed in different folders. Files of component libraries (tmdevenv.tmul) (which have different formats for different IDEs) are placed if following folders:
c:\ProgramData\AdAstra\Trace Mode IDE 6\
and
c:\ProgramData\AdAstra\Trace Mode IDE 6 Base\
(OS’es Windows 7 and Windows 8.1)
c\:Documents and Settings\All Users\Application Data\AdAstra\Trace Mode IDE 6\
and
c\:Documents and Settings\All Users\Application Data\AdAstra\Trace Mode IDE 6 Base\
(OS Windows XP).

In order to use files of user component library (tmdevenv.tmul), copy this file from subdirectory %TRACE MODE%\LIB to to one of (existing) above mentioned directory (%TRACE MODE% is IDE’s root).

    New Features of SCADA TRACE MODE 6.10.2 Software Update

    Note! Since the release 6.10.2, software upgrades are available only through User's Personal Account (updates are free-of-charge). The registered programs can be downloaded only. Program registration is also carried out through the user's personal account. Registration information is on the registration card of the software and in the license agreement.

    For inquiries, please contact: http://forum.tracemode.com/.

TOP NEWS

Training Video: Connecting Mitsubishi FX3U PLC to TRACE MODE SCADA/HMI via Melsec Protocol

Melsec FX3U and SCADA/HMI TRACE MODELearn how to connect a Mitsubishi Melsec FX3U PLC to TRACE MODE SCADA/HMI through built-in driver with our new free online video training.

To run the film just ....

 

SCADA For GSM/GPRS-based Remote Control Now Released

Doc GSM RTM+ TRACE MODE

AdAstrA Research Group (Moscow, Russia) has launched a new SCADA/HMI class software product - TRACE MODE GSM RTM+ for GSM/GPRS-based remote control and alarming.

Utility, transportation, hi-tech house, water, gaz, fire-safety and agriculture remote control – the all-new SCADA/HMI software is designed for a range of applications that seek to receive real-time process data and communicate them to the mobile teams in a fast and reliable way. 

TRACE MODE GSM RTM+ is easily programmed on IEC 6-1131/3 visual languages in SCADA/HMI TRACE MODE 6 integrated development environment.

TRACE MODE Data Center Provides Remote Web Based And Mobile Access to Control Systems

AdAstrA Research Group has released a new SCADA TRACE MODE runtime module, TRACE MODE Data Center, providing remote access to real-time control system information using web-browser via Internet/Intranet or wireless networks (GSM, GPRS, Wi-Fi, Bluetooth).

The all-new product from AdAstra is tailored to meet the needs of the corporate users of TRACE MODE looking to consolidate information from the various control systems across the plant, and provide access to this information for mobile employees, such as engineers, chief engineers, and plant management.

 

New free of charge drivers for TOSHIBA TOSVERT Added in TRACE MODE SCADA/HMI

New free of charge drivers for TOSHIBA TOSVERT series frequency converters are added to the TRACE MODE SCADA/HMI software and published at the AdAstra Web site for download:
  • TOSVERT.VF-nC1
  • TOSVERT.VF-S9
  • TOSVERT.VF-P7

SCADA TRACE MODE 6.05 Now Avaiable

On January 30, 2007, a new release of the integrated SCADA-system TRACE MODE 6.05 has been made available, both in Professional and Standard editions.

The 6.05 release includes new features and patches for the development system and runtime modules. The new SCADA TRACE MODE and MES-EAM-HRM software from the T-FACTORY system is available for free download from the support section.

SCADA HMI TRACE MODE Supports BACnet Protocol

BACnet

The BACnet protocol support strengthen the SCADA TRACE MODE 6 positions in the field of building automation and hi-tech house applications.

The ready-to-use example of the SCADA TRACE MODE 6 connectivity to the YORK TDC9E PLC using BACnet/IP protocol is available for free download at the SUPPORT section of the site.

LAST NEWS

Adastra Releases TRACE MODE 6 RTM for Linux

RTM TRACE MODE 6 for LinuxAdAstra Company (Russia) announced the release of real-time monitor (LinRTM) for the operating system Linux.

TRACE MODE RTM is the main runtime module of the integrated TRACE MODE 6 SCADA/HMI software, designed to operate on operator workstations.

The new LinRTM provides ...

A New Free Driver for OMRON Sysmac PLC

omron plcAdAstra Research Group (Moscow, Russia) has released a new version of the free TRACE MODE SCADA/HMI driver for the OMRON programmable logical controller. The new driver is built in the TRACE MODE SCADA/HMI 6.09 release and above.

video tutorial demonstrating the technology of OMRON PLCs connecting over the network via UDP using the free built-in driver, is available.OMRON Logo

The new driver is much faster, easier and more functional than the previous ones. The new TRACE MODE OMRON PLC driver has the following important features...

TRACE MODE 6.07.7 SCADA/HMI Now Released

AdAstrA's Technical Support team announces a new SCADA TRACE MODE 6.07.7 release.

The 6.07.7 release makes TRACE MODE 6 fully compatible with 32-bit and 64-bit versions of Windows 7, while also introducing exciting new features...

AdAstrA Releases TRACE MODE 6.07

AdAstrA Support team announces a new SCADA TRACE MODE 6.07 release.

TRACE MODE 6.07  features new development tools for electricity metering systems and building automation.
 
Starting with 6.07 release, SCADA TRACE MODE offers an all-in-one driver that supports a variety of protocols used in different electricity meters.

Besides new TRACE MODE 6.07 releas includes new graphical elements for building automation amd electricity metering systems.

AdAstrA Reseases a New Milestone Release, SCADA TRACE MODE 6.06!

AdAstrA launched a new release of the integrated SOFTLOGIC-SCADA-MES-EAM-HRM system, TRACE MODE 6.06, available both in Professional and Base editions. The exciting new 6.06 release provides a host of new features and technologies to dramatically increase SCADA TRACE MODE performance and functionality.

New SCADA TRACE MODE updates are available free of charge at the Support section.

HART Driver for Micro TRACE MODE 6 to Connect HART Devices and WinCon 8000

AdAstrA Research Group, Ltd made available an external driver for Micro TRACE MODE 6 industrial controller programming system. This driver is designed to connect WinCon 8000 controller to sensors and flowmeters using a popular HART protocol.

The Kristall distillery in Moscow was one of the first factories to deploy the HART driver for WinCon 8000. Previously, Micro TRACE MODE 6 for WinCon 8000 was shipped only with the integrated drivers for Modbus RTU, Modbus TCP, DCS, etc.

SCADA HMI TRACE MODE 6

Current TRACE MODE release 6.10.2. Upgrade now for free!



NEWS